Résumé
As part of the work under International Electrotechnical Commission (IEC) SC 61D for safety of air conditioners, rules for extending charge of A2 and A3 refrigerants (with respect to room size) are under development within the working group, WG16. Requirements have evolved to utilise airflow from indoor units (IDUs) to dilute any possible leak of flammable refrigerant. Research has been carried out to determine the minimum airflow rate necessary to achieve sufficient dilution of the flammable mixtures and a numerical model based on entrainment theory was developed and previously validated for A3 refrigerants. New IEC 60335-2-40: 2018 which includes revisions specifically for A2Ls contains rules for determining IDU airflow requirements but were not validated and in several respects are contradictory. Therefore the method developed for A2 and A3 refrigerants under WG16 need to be assessed with respect to extending its application to A2L refrigerants.
Documents disponibles
Format PDF
Pages : 11
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Minimum airflow rates to dilute A2L refrigerant leaks from refrigeration systems.
- Identifiant de la fiche : 30024881
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1189
Liens
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Minimum airflow rates to dilute A2L refrigerant...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Ignition sources at the stage of usage for mini...
- Auteurs : TAMURA K., TAKAICHI K., TAIRA S., BABA A., ITAKURA S., MORI H., MAKINO H.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
The application and risk assessment of R290 in ...
- Auteurs : HE G., SUN W., TANG W., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Theoretical and simulation analysis for R290 le...
- Auteurs : NING Q., HE G., LI B., LI T.
- Date : 10/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 166
- Formats : PDF
Voir la fiche
-
A3 Refrigerant R290 Leak and Ignition Testing f...
- Auteurs : WANG H., HUNTER G.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche