Déploiement du R290 dans les chauffe-eaux à pompe à chaleur et implications pour la décarbonation.
Deployment of R290 in heat pump water heaters and implications for decarbonization.
Numéro : 2466
Auteurs : NAWAZ K., RENDALL J., ELATAR A., SUN J.
Résumé
Growing awareness of the potential environmental impacts of various refrigerants has led to the phasedown of hydrofluorocarbon (HFC) refrigerants and initiatives replacing HFCs with hydrocarbons or other environmentally friendlier fluids. This study evaluated the performance of R290 (propane) as a substitute for R134a (an HFC) for heat pump water heating (HPWH). Comprehensive experimentation is performed to predict the performance of propane as a refrigerant for a domestic HPWH. Key performance parameters such as unified energy factor, first-hour rating, and total refrigerant charge have been established and compared to the baseline system based on R134a. To reduce the refrigerant charge in the system, a comprehensive work plan has been developed that focuses on individual components including the evaporator, compressor, and condenser. Based on one-to-one comparison it has been found that an R290 system can provide comparable performance with a substantially lower amount of refrigerant charge. The study aims to develop a roadmap for next-generation heat pump water heaters compatible with hydrocarbons as refrigerants and can be deployed safely for domestic applications.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Gratuit
Détails
- Titre original : Deployment of R290 in heat pump water heaters and implications for decarbonization.
- Identifiant de la fiche : 30033112
- Langues : Anglais
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 17/07/2024
Liens
Voir d'autres communications du même compte rendu (187)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Hydrocarbures;
Pompes à chaleur, récupération d'énergie : généralités - Mots-clés : R290; Substitut; Charge en frigorigène; R134a; Performance; Comparaison
-
Deployment of R290 in heat pump water heaters a...
- Auteurs : NAWAZ K., RENDALL J., ELATAR A., SUN J.
- Date : 08/2024
- Langues : Anglais
- Source : 16th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2024). Proceedings. University of Maryland, College Park, Maryland, USA, August 11-14 2024
- Formats : PDF
Voir la fiche
-
REFRIGERANT CHARGE EFFECTS ON HEAT PUMP PERFORM...
- Auteurs : DAMASCENO G. S.
- Date : 1991
- Langues : Anglais
Voir la fiche
-
THE EFFECT OF VOID FRACTION CORRELATION AND HEA...
- Auteurs : RICE C. K.
- Date : 1987
- Langues : Anglais
Voir la fiche
-
European heat pump market data – Evolution of t...
- Auteurs : OLTERSDORF T., FUGMANN H., SCHNABEL L.
- Date : 05/2023
- Langues : Anglais
- Source : 14th IEA Heat Pump Conference 2023, Chicago, Illinois.
- Formats : PDF
Voir la fiche
-
A proposal of sustainability figures illustrati...
- Auteurs : OLTERSDORF T., SCHNABEL L., FUGMANN H.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche