Résumé
The study investigated how to detect refrigerant inventory in a system air conditioner with multiple indoor units for an outdoor unit. Due to the complexity of the system, it is difficult to detect the refrigerant inventory charged in the system air conditioner compared with that in a single air conditioner. Tests were performed for 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The measured refrigerant inventory ranged from 60 to 140% with 10% interval. A fuzzy algorithm was employed for detecting the refrigerant inventory in the system air conditioner. Measured data were utilized to find out the curve fitting under indoor and outdoor temperature conditions. The functions were determined within the whole range of measured data and rule-based functions were defined for each refrigerant inventory. The programme developed predicted the measured data within a 10% error range.
Détails
- Titre original : Fault detection for the refrigerant inventory of the system air conditioner.
- Identifiant de la fiche : 2007-0799
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
- Date d'édition : 21/05/2006
Liens
Voir d'autres communications du même compte rendu (161)
Voir le compte rendu de la conférence
-
Bestimmung von Kältemittelfüllmenge und Sammler...
- Auteurs : LINCK W., GIEBE M.
- Date : 11/1999
- Langues : Allemand
- Source : Kälte + Klimatechnik (Die) - vol. 52 - n. 11
Voir la fiche
-
Oil influence on the optimal charge and perform...
- Auteurs : MARTÍNEZ-GALVÁN I., GONZÁLVEZ-MACIÁ J., CORBERÁN J. M., et al.
- Date : 06/04/2009
- Langues : Anglais
- Source : RCR 2009. 1st IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems.
- Formats : PDF
Voir la fiche
-
Computing the partial volume of pressure vessels.
- Auteurs : WIENCKE B.
- Date : 06/2010
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 4
- Formats : PDF
Voir la fiche
-
Study on the technical characteristics of DVM a...
- Auteurs : SHAO Z., CHEN H., LIU J.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
A hybrid deep forest approach for outlier detec...
- Auteurs : ZENG Y., CHEN H., XU C., CHENG Y., GONG Q.
- Date : 12/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 120
- Formats : PDF
Voir la fiche