Résumé
Because of the moderate climate of Japan, most of the air conditioners (A/Cs) used are split-type A/Cs and can provide both heating and cooling during the year. Therefore, the coefficient of performance (COP) and the annual performance factor (APF) are used as criteria to evaluate the annual average performance of A/Cs; these criteria are established on the basis of Japanese Industrial Standards (JIS). The JIS-based performance rating method is easy and useful but does not take into account the intermittently driven mode of the compressor. In practice, A/Cs are mainly operated under partial load conditions, which are often 30–50% of the full load. In this study, partial load tests were conducted for three different room air conditioners, and the measured APFs were compared to those calculated using the JIS-based calculation method. Because the inverter-driven compressors, which are widely used in A/C systems, are driven intermittently when the load is small and show low COP, the measured APFs were found to be much lower than those calculated using the JIS-based method when taking into account the intermittently driven mode. It is suggested that the JIS be revised by considering the performance deterioration at low load conditions.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Study on annual performance of room air conditioners under partial load condition.
- Identifiant de la fiche : 30006383
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (195)
Voir le compte rendu de la conférence
-
Modeling of variable refrigerant flow system fo...
- Auteurs : KWON L., HWANG Y., RADERMACHER R., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental study on multi-split air condition...
- Auteurs : TU Q., DONG K. J., ZOU D., et al.
- Date : 10/2011
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 31 - n. 14-15
Voir la fiche
-
Study on the technical characteristics of DVM a...
- Auteurs : SHAO Z., CHEN H., LIU J.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Theoretical and simulation analysis for R290 le...
- Auteurs : NING Q., HE G., LI B., LI T.
- Date : 10/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 166
- Formats : PDF
Voir la fiche
-
Split-systems : climatiseurs à éléments séparés...
- Auteurs : JACQUARD P.
- Date : 08/2000
- Langues : Français
- Source : CLIM Prat. - n. 33
Voir la fiche