Document IIF

Développement d'un modèle de stabilité pour la bande d'étanchéité unique d'un rideau d'air à recirculation dans une enceinte frigorifique.

Development of a stability model for a vertical single band recirculated air curtain sealing a refrigerated cavity.

Auteurs : HAMMOND E., QUARINI J., FOSTER A.

Type d'article : Article, Article de la RIF

Résumé

Recirculating cold air curtains are used to seal the open front of all multi-deck refrigerated display cabinets commonly used in food retail. Infiltration through the air curtain has been estimated to be the source of between 78 and 81% of the total heat gain to the cabinet. More efficient air curtains would not only save energy but would enable more precise temperature control of the produce within the display cabinet, better preserving food quality. Curtain thickness, length, discharge temperature and velocity all influence the efficiency of the air curtain and design optimisation has until recently been largely empirical or has used complex CFD models.
The aim of this study was to generate a design guide which would enable cabinet designers with limited fluid flow expertise to rapidly identify the most efficient air curtain design to seal any given cavity from fundamental measurements without any need for intensive computation.

Documents disponibles

Format PDF

Pages : 1455-1461

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Development of a stability model for a vertical single band recirculated air curtain sealing a refrigerated cavity.
  • Identifiant de la fiche : 30001534
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 6