Développement d'un système à absorption de type 2, pour le transport d'énergie, utilisant le GNL comme source froide.
Development of type 2 solution transportation absorption system for utilizing LNG cold energy.
Résumé
The objective of this paper is to develop a new energy transport system for district cooling application by using type 2 absorption cycle. Cold energy from the LNG storage system is utilized as the cooling source of the condenser and the rectifier. The pressures of the system, UAs of the evaporator and the desorber, the inlet temperatures of the refrigerant for each component, transportation distance and the pumping power per unit length are considered as the key parameters. The results show that UA of the evaporator has more dominant effect on COP than that of the desorber. The optimum system pressure for the demand side is also determined. For the present system, it is recommended that the refrigerant inlet temperature of the evaporator be lower than 4.3°C for long distance transportation. It is concluded that the cold energy from the LNG storage system can be effectively applied to the long distance transportation system for district cooling application with the type 2 absorption cycle. The maximum transportation distance and the pumping power per unit length are calculated. The optimum operation conditions are also predicted from the parametric analysis.
Documents disponibles
Format PDF
Pages : 978-985
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Development of type 2 solution transportation absorption system for utilizing LNG cold energy.
- Identifiant de la fiche : 2007-2764
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 6
- Date d'édition : 09/2007
Liens
Voir d'autres articles du même numéro (16)
Voir la source
Indexation
-
Ammonia absorption chillers in district cooling...
- Auteurs : CERKVENIK B., ZIHER D., POREDOS A.
- Date : 06/05/2005
- Langues : Anglais
- Source : Ammonia Refrigerating Systems, Renewal and Improvement.
- Formats : PDF
Voir la fiche
-
Refroidisseur à absorption original pour les ré...
- Auteurs : SCHWEIGLER C., HELLMANN H. M., DEMMEL S.
- Date : 07/1996
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 32 - n. 7
Voir la fiche
-
Göteborg Energi AB offers district cooling by u...
- Auteurs : HELLBERG S.
- Date : 02/06/1997
- Langues : Anglais
- Source : Ab-sorption machines for heating and cooling in future energy systems. Workshop proceedings.
Voir la fiche
-
Le froid à partir du chauffage urbain.
- Auteurs : ZIEMANN O., SCHWEIGLER C., et al.
- Date : 12/1996
- Langues : Allemand
- Source : Euroheat Power Fernwärme int. - vol. 25 - n. 12
Voir la fiche
-
Operation and performance of a 350 kilowatt sin...
- Auteurs : SCHWEIGLER C. J., HELLMANN H. M., PREISSNER M., DEMMEL S., ZIEGLER F. F.
- Date : 1998
- Langues : Anglais
- Source : ASHRAE Transactions. 1998 Winter Meeting, San Francisco, CA.
Voir la fiche