Développement d'une méthode d'évaluation de la performance d'un système de conditionnement d'air split utilisant la courbe caractéristique du compresseur.
Development of the performance evaluation method for a split air conditioning system using the compressor characteristic curve.
Numéro : pap. n. R16, 2221
Auteurs : WAKAHARA T., IMANARI T., NOBE T., et al.
Résumé
This paper deals with the development of the performance evaluation method for a split air conditioning system using the compressor characteristic curve. In split air, air conditioning system, refrigerants expand directly in an evaporator and heat-exchange is done on the indoor unit. it is too difficult to measure the actual capacity and the accurate performance evaluation method is not established. The performance evaluation method using the compressor curve method based on the characteristic curve of compressor mass flow rate was developed. The authors examine the application of the method to this system which has different compressor type. The regression equations for refrigerant mass flow rate were obtained based on characteristic curve of the sliding vane compressor. The relative error between air conditioning capacity based on measurement and regression equation is obtained within 9.0%. The applicability of method for another type compressor is confirmed.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Development of the performance evaluation method for a split air conditioning system using the compressor characteristic curve.
- Identifiant de la fiche : 30000771
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 12/07/2010
Liens
Voir d'autres communications du même compte rendu (121)
Voir le compte rendu de la conférence
-
A network model to simulate performance of vari...
- Auteurs : SHI W., SHAO S., LI X., et al.
- Date : 2003
- Langues : Anglais
- Source : ASHRAE Transactions. 2003 annual Meeting, Kansas City, Missouri, USA. Volume 109, part 2 + CD-ROM.
Voir la fiche
-
Use of condensate drain to pre-cool the inlet a...
- Auteurs : SAWAN R., GHALI K., HINDI M. al-
- Date : 06/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 3
Voir la fiche
-
Influence des paramètres environnementaux et ca...
- Auteurs : CHILENKO V. I., PIMKOV A. L., VERCHININ V. S., et al.
- Date : 2000
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 11
Voir la fiche
-
Performance comparisons of a unitary split syst...
- Auteurs : KIM J. H., GROLL E. A.
- Date : 2003
- Langues : Anglais
- Source : ASHRAE Transactions. 2003 annual Meeting, Kansas City, Missouri, USA. Volume 109, part 2 + CD-ROM.
Voir la fiche
-
Modeling of dynamic characteristics for a split...
- Auteurs : CHEN Z. J., SONG X. H., ZHANG C. L., QUE X. C.
- Date : 09/09/1997
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
Voir la fiche