This paper deals with the development of the performance evaluation method for a split air conditioning system using the compressor characteristic curve. In split air, air conditioning system, refrigerants expand directly in an evaporator and heat-exchange is done on the indoor unit. it is too difficult to measure the actual capacity and the accurate performance evaluation method is not established. The performance evaluation method using the compressor curve method based on the characteristic curve of compressor mass flow rate was developed. The authors examine the application of the method to this system which has different compressor type. The regression equations for refrigerant mass flow rate were obtained based on characteristic curve of the sliding vane compressor. The relative error between air conditioning capacity based on measurement and regression equation is obtained within 9.0%. The applicability of method for another type compressor is confirmed.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Development of the performance evaluation method for a split air conditioning system using the compressor characteristic curve.
- Record ID : 30000771
- Languages: English
- Source: 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2010/07/12
Links
See other articles from the proceedings (121)
See the conference proceedings
-
A network model to simulate performance of vari...
- Author(s) : SHI W., SHAO S., LI X., et al.
- Date : 2003
- Languages : English
- Source: ASHRAE Transactions. 2003 annual Meeting, Kansas City, Missouri, USA. Volume 109, part 2 + CD-ROM.
View record
-
Testing and modelling of a bisplit refrigeratio...
- Author(s) : GRODENT M., LOPES S., BORG S.
- Date : 1997/08
- Languages : English
- Source: CLIMA 2000, Brussels 1997, August 30 to September 2, Congress Palace.
View record
-
Simplified modelling of variable refrigerant fl...
- Author(s) : FILFLI S., MARCHIO D.
- Date : 2006/02
- Languages : English
- Source: Eurovent-Cecomaf, Rev. - n. 83
View record
-
Evaluation and modelling of split-system air co...
- Author(s) : RICE C. K.
- Date : 2005/12
- Languages : English
View record
-
Klimatisieren mit der elektro- bzw. mit der gas...
- Author(s) : ISELT P.
- Date : 2006/04
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 59 - n. 4
View record