Résumé
Japan Atomic Agency (JAEA) has developed leak detection technology for liquid helium temperature experiments in large-scale superconducting magnet test facilities. In JAEA, a cryosorption pump that uses an absorbent cooled by liquid nitrogen with a conventional helium leak detector, is used to detect helium gas that is leaking from pressurized welded joints of pipes and valves in a vacuum chamber. The cryosorption pump plays the role of decreasing aerial components, such as water, nitrogen and oxygen, to increase the sensitivity of helium leak detection. A total of 850 welded and mechanical joints inside the cryogenics test facility for the ITER Central Solenoid Model Coil experiments have been tested. In the test facility, 73 units of glass fiber-reinforced plastic insulation break are used.
Détails
- Titre original : [In Japanese. / En japonais.]
- Identifiant de la fiche : 2006-2793
- Langues : Japonais
- Source : Journal of the Cryogenic Society of Japan - vol. 41 - n. 3
- Date d'édition : 2006
Liens
Voir la source
Indexation
-
USE OF < FIVE-MINUTE EPOXY > AS A CRYOGENIC LEA...
- Auteurs : MARTIN D. L.
- Date : 1987
- Langues : Anglais
- Source : Rev. sci. Instrum. - vol. 58 - n. 2
Voir la fiche
-
TUYAUTERIES CRYOGENIQUES (CONDUITES DE TRANSFERT).
- Auteurs : OGATA H.
- Date : 1984
- Langues : Japonais
- Source : Cryogenics/ Cryog. Eng. - vol. 19 - n. 4
Voir la fiche
-
LIQUID HELIUM PUMPS FOR IN-ORBIT TRANSFER.
- Auteurs : KITTEL P.
- Date : 1987
- Langues : Anglais
- Source : Cryogenics - vol. 27 - n. 2
Voir la fiche
-
VERY LOW LOSS LIQUID HELIUM TRANSFER WITH LONG ...
- Auteurs : BLESSING H., LEBRUN P., SCHIPPL K.
- Date : 1990
- Langues : Anglais
- Source : Adv. cryog. Eng. - vol. 35 B
Voir la fiche
-
Analyse numérique des fuites thermiques d'un ré...
- Auteurs : SHIMAMURA Y., ASAI O., YAMAGUCHI M., OHMORI T.
- Date : 1992
- Langues : Japonais
- Source : Ishikawajima-Harima Giho - vol. 32 - n. 3
Voir la fiche