Développement d'une pompe à chaleur au CO2 d'une puissance de 9 kW (triphasée, 400 V) utilisée pour chauffer de l'eau sanitaire, pour le marché européen.

The development of the 9 kW CO2 heat pump water heater (3 phase 400 V) for the European market.

Auteurs : MERINO S., KOBORI Y., ITO H.

Résumé

In Japan, the sales of the CO2 heat pump water heaters "Ecocute" (that use CO2 natural refrigerant) are increasing year by year. Moreover, the multifunction version of the Ecocute has being requested from the market, so Sanyo put on the market the first multifunctional (domestic hot water and space heating) unit for cold areas. In this time SANYO adopted this technology and developed the first 9 kW CO2 split-cycle unit (for household use) for the European market.

Détails

  • Titre original : The development of the 9 kW CO2 heat pump water heater (3 phase 400 V) for the European market.
  • Identifiant de la fiche : 2011-0320
  • Langues : Anglais
  • Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
  • Date d'édition : 17/02/2010

Liens


Voir d'autres communications du même compte rendu (75)
Voir le compte rendu de la conférence