Document IIF
Développement et caractérisation de la performance d'une pompe à chaleur eau-eau réversible fonctionnant au propane.
Development and performance characterisation of a water to water reversible heat pump working with propane.
Auteurs : CORBERÁN J. M., GONZÁLVEZ J., MARTÍNEZ I. O., et al.
Résumé
This paper presents a summary of the development and performance study of a reversible water to water heat pump working with propane (R290) and designed for a nominal cooling capacity of 16 kW. The paper describes the steps involved in the design of the heat pump working with propane as opposed to the reference R407C unit, with regard to all system components: compressor, heat exchangers, expansion valve and refrigerant circuit. A semihermetic compressor had to be employed for the propane prototype since no scroll compressor manufacturer allows for the moment the use of their compressors with flammable refrigerants. Special care was taken in the reduction of the volume of the refrigerant circuit in order to minimise the propane charge. The prototype gave excellent performance with superior COP on both refrigeration and heating modes in comparison with the reference R407C unit.
Documents disponibles
Format PDF
Pages : 2008-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Development and performance characterisation of a water to water reversible heat pump working with propane.
- Identifiant de la fiche : 2009-0379
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Date d'édition : 07/09/2008
Liens
Voir d'autres communications du même compte rendu (132)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Hydrocarbures;
Mélanges - Mots-clés : R407C; Comparaison; Conception; Prototype; Propane; Pompe à chaleur; Performance; Experimentation; COP; Frigorigène; Conditionnement d'air; Eau-eau
-
Charge and COP optimization of a reversible wat...
- Auteurs : MARTÍNEZ I. O., GONZÁLVEZ J., CORBERÁN J. M.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Performance of heat pumps charged with R170/R29...
- Auteurs : KANG D. G., PARK K. J., JUNG D.
- Date : 23/06/2009
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Performance of a 100 kW low charge heat pump us...
- Auteurs : DEL COL D., CAVALLINI A., DA RIVA E., et al.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
Propane as refrigerant in a small heat pump. Sa...
- Auteurs : GRANRYD E., TENGBLAD N., NOWACKI J. E.
- Date : 10/05/1994
- Langues : Anglais
- Source : New Applications of Natural Working Fluids in Refrigeration and Air Conditioning
- Formats : PDF
Voir la fiche
-
Comparison of TEWI for fluorocarbon alternative...
- Auteurs : SAND J. R., FISCHER S. K., BAXTER D. van
- Date : 1999
- Langues : Anglais
- Source : ASHRAE Transactions. 1999 Winter Meeting, Chicago, Illinois + CD-ROM.
Voir la fiche