Distribution de l’écoulement diphasique air-eau dans un collecteur raccordé à quatre unités intérieures d’un système à débit de frigorigène variable (VRF).
Air-water two-phase flow distribution in a manifold having four indoor-unit connections of a VRF system.
Résumé
In case of a Variable refrigerant flow(VRF) system, the refrigerant is supplied from one outdoor unit to a number of indoor units through manifold-shaped distributors. As the height difference between the distributors increases, the refrigerant may enter the distributor in two-phase state due to the pressure drop. Therefore, this study experimentally investigated the flow distribution characteristics in a distributor with four branches using air-water as a working fluid. Most of the literature deals only with the case where the working fluid is supplied from one inlet. However, for a VRF system depending on the mode of the indoor unit, the working fluid is supplied from both the inlet and branch. Therefore, the characteristics of two-phase flow distribution were investigated through three experimental cases considered in the flow arrangements varied by operation mode of the indoor unit. The experimental data of the two-phase flow distribution were obtained by varying void fraction, mass flow rate, and downstream flow resistance in the branch for each case. The unevenness of the distribution was suggested by the difference of liquid fraction where the liquid was most distributed and where it was least distributed.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Air-water two-phase flow distribution in a manifold having four indoor-unit connections of a VRF system.
- Identifiant de la fiche : 30026052
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0909
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
SOUND DATA CORRELATION AND ANALYSIS FOR A VAV T...
- Auteurs : MILLER P. L. Jr, BALL H. D.
- Date : 1983
- Langues : Anglais
Voir la fiche
-
Simulation and experimental validation of the v...
- Auteurs : HE C., JIN X., DU Z., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Improvement of two-phase refrigerant distributi...
- Auteurs : KIM N. H., LEE E. J., BYUN H. W.
- Date : 09/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 59 - n. 1-2
Voir la fiche
-
Effect of inlet configuration on the two-phase ...
- Auteurs : KIM D. Y., KIM N. H., BYUN H. W., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Evaluation of VRF system with multi indoor unit...
- Auteurs : MATSUMOTO K., OHNO K., SAITO K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche