ECHANGEURS AIR-AIR POUR LOCAUX RESIDENTIELS. PERFORMANCE, ECONOMIES D'ENERGIE ET RENTABILITE.

RESIDENTIAL AIR TO AIR HEAT EXCHANGERS. PERFORMANCE, ENERGY SAVINGS, AND ECONOMICS.

Auteurs : FISK W. J., TURIEL I.

Type d'article : Article

Résumé

LA CONSOMMATION D'ENERGIE PAR LES IMMEUBLES RESIDENTIELS PEUT ETRE ABAISSEE SI L'ON REDUIT LES INFILTRATIONS D'AIR. CETTE REDUCTION PEUT ENTRAINER DES PROBLEMES DE QUALITE DE L'AIR INTERIEUR (HUMIDITE EXCESSIVE, NIVEAUX ELEVES DE CONTAMINANTS). UNE SOLUTION CONSISTE A INSTALLER UN ECHANGEUR DE CHALEUR AIR-AIR POUR LOCAUX RESIDENTIELS FOURNISSANT UN APPORT REGULE DE VENTILATION ET RECUPERANT L'ENERGIE NORMALEMENT PERDUE PAR INFILTRATION D'AIR. ON EXAMINE LA PERFORMANCE DE CES ECHANGEURS DE CHALEUR, ON RECAPITULE LES RESULTATS D'ESSAIS DE PLUSIEURS MODELES. ON COMPARE L'ENERGIE CONSOMMEE AU COURS DE LA SAISON DE CHAUFFAGE DANS LES MAISONS A FAIBLE INFILTRATION. L'ENERGIE NECESSAIRE POUR CHAUFFER L'AIR DE RENOUVELLEMENT DANS LES MAISONS EMPLOYANT DES ECHANGEURS DE CHALEUR EST INFERIEURE DE 5,3 A 18,0 GJ A CELLE DES MAISONS TYPIQUES. LE SYSTEME DE VENTILATEUR DE L'ECHANGEUR DE CHALEUR A EXIGE 2,2 A 3,6 GJ D'ENERGIE S ET LES PERIODES D'AMORTISSEMENT DEDUITES VARIAIENT DE 5 A PLUS DE 30 ANS. (INT. BUILD. SERV. ABSTR., GB., 18, N.5, 1983, 22, 83-01609.

Détails

  • Titre original : RESIDENTIAL AIR TO AIR HEAT EXCHANGERS. PERFORMANCE, ENERGY SAVINGS, AND ECONOMICS.
  • Identifiant de la fiche : 1984-2078
  • Langues : Anglais
  • Source : Energy Build. - vol. 5 - n. 3
  • Date d'édition : 1983
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir la source