Economies dans les circuits hydrauliques pour les centres de données : considérations sur la conception et la régulation.
Waterside economizing in data centers: design and control considerations.
Auteurs : STEIN J.
Résumé
Free cooling was not common in data centers in the past for a variety of reasons including the philosophy that data center cooling should be designed for maximum reliability and not for energy efficiency. Recently times have changed. Energy and sustainability are more important to many data center owners now and sophisticated owners and designers know that free cooling can provide a good return on investment while still maintaining adequate reliability. Many data centers are being designed or retrofitted with airside economizers, waterside economizers, and even "wet bulb" economizers (direct evaporative coolers). This paper briefly compares airside and waterside economizers, then briefly compares the two types of waterside economizers (CRAC and chiller plant) and then focuses on design and control considerations for chiller plant waterside economizers serving data centers.
Détails
- Titre original : Waterside economizing in data centers: design and control considerations.
- Identifiant de la fiche : 2010-0228
- Langues : Anglais
- Source : 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
- Date d'édition : 21/06/2009
Liens
- Liens externes :
Voir d'autres communications du même compte rendu (30)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Conditionnement d’air dans les laboratoires et l’industrie;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : Économie; Centre de données; Comparaison; Conception; Régulation; Synthèse; Froid naturel; Conditionnement d'air; Échangeur de chaleur; Circuit hydraulique
-
La progettazione del risparmio energetico negli...
- Auteurs : TRECATE R., VIO M.
- Date : 07/03/2002
- Langues : Italien
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
Voir la fiche
-
Visokoefikasno hladenje racunskog centra dinami...
- Auteurs : AIT YOUNES K.
- Date : 03/12/2008
- Langues : Serbe
- Source : Zbornik radova. 39. Medunarodni kongres o grejanju, hladenju i klimatizaciji.
- Formats : PDF
Voir la fiche
-
Liquid cooling architectures for computer syste...
- Auteurs : ELLSWORTH M. J., SCHMIDT R. R.
- Date : 23/06/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
Voir la fiche
-
Comparison between underfloor supply and overhe...
- Auteurs : SCHMIDT R. R., IYENGAR M.
- Date : 27/01/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
Voir la fiche
-
IMPORTANT CONSIDERATIONS IN COMPUTER ROOM HUMID...
- Auteurs : DEACON W. T.
- Date : 1989
- Langues : Anglais
Voir la fiche