Document IIF

Écoulement thermodynamique non équilibré de R600a à la sortie du condenseur d'un cycle frigorifique à compression de vapeur.

Thermodynamic non-equilibrium flow of R600a at the outlet of a condenser of a vapor compression refrigeration cycle.

Numéro : pap. 1153

Auteurs : SEO J. Y., JEONG J. H.

Résumé

To keep in tandem with modern technologies, food storage became easier with domestic refrigerators. In domestic refrigerators, refrigerant phase behavior can be a fundamental problem especially in nonequilibrium conditions. In the refrigeration cycles for better cooling capacity and performance, condenser outlet refrigerant condition should be subcooled. In this study, an experimental apparatus of a refrigeration cycle with R600a as a refrigerant assembled. Also, experimental apparatus equipped with several
thermocouples, pressure instruments, ultrasonic device and transparent tube at the subcooled region to visualize the refrigerant state and calculating the void fraction. According to temperature and pressure results at condenser outlet, the refrigerant state should be subcooled but experimental results observed two-phase state. To recognize the thermodynamic state for R600a, a new alternative equation suggested defining the refrigerant enthalpy based on the void fraction. Also, for validation this equation, some experiments were conducted in the various operating conditions of the refrigeration system.

Documents disponibles

Format PDF

Pages : 7 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Thermodynamic non-equilibrium flow of R600a at the outlet of a condenser of a vapor compression refrigeration cycle.
  • Identifiant de la fiche : 30019175
  • Langues : Anglais
  • Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.