Effet du changement de la température de saturation dû à la chute de pression des frigorigènes sur la puissance de transfert de chaleur de l'échangeur thermique.
Effect of saturation temperature change due to pressure loss of refrigerants on heat transfer capacity of heat exchanger.
Numéro : pap. 2201
Auteurs : LEE H., JEONG J. H.
Résumé
Heat exchanger is an essential component in the HVAC&R applications. The heat exchanger development methods are divided into simulation and experiment. Simulation is often used by researchers because it can save a lot of time and money over experimental method. However, it is difficult to model all physical phenomena in simulation. Some phenomena are simulated with ideal assumptions based on experience. To analyze an ideal heat exchanger without pressure loss of the refrigerant, the saturation temperature of the heat exchanger is assumed to be constant. Whereas, saturated temperature drop occurs due to the pressure loss of the refrigerant in a real case scenario which affects the heat transfer capacity of the heat exchanger. In this study, a theoretical method to evaluate the effect of saturated pressure loss of refrigerant on the heat transfer capacity in heat exchanger was proposed and analyzed. The proposed method was verified by simulation. R134a, R410A, R600a, R32, and R1234yf were selected as refrigerants for analysis which are used in air conditioners and refrigerators. As a result, the heat transfer capacity ratio of the cycle using R134a showed 96.11% under the condensing condition of 15 kPa pressure loss, and 108.97% and 123.17% for air conditioner and refrigerator evaporating conditions, respectively. Moreover, R600a showed the greatest performance change, and R32 showed the smallest performance change.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of saturation temperature change due to pressure loss of refrigerants on heat transfer capacity of heat exchanger.
- Identifiant de la fiche : 30024444
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
-
Experimental investigations of propane minichan...
- Auteurs : GAGAN J., BUTRYMOWICZ D., DUDAR A., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
A generalized effectiveness-NTU based variable ...
- Auteurs : HUANG L., AUTE V., RADERMACHER R.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
CFD-based correlation development for air side ...
- Auteurs : BACELLAR D., AUTE V., RADERMACHER R.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Experimental analysis of peripheral finned-tube...
- Auteurs : PUSSOLI B. F., BARBOSA J. R. Jr, SILVA L. W. da, et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Study on the numerical modeling of convective h...
- Auteurs : LEE G., CHOI J., JOUNG T., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche