Résumé

The magnetocaloric effect (MCE) of the Gd-dopped Ni-Cu-Mn-Ga polycrystalline alloy was investigated. The nominal composition of the alloy was Ni 50, Cu 6.25, Mn 16.75, Ga 25 and Gd 2 at.%. The XRD studies revealed presence of two phases at room temperature (RT). This was confirmed by magnetic measurements conducted in low field of 4 kA/m (50 Oe), which showed two Curie transition temperatures, one in vicinity and the other one well above the RT. The analysis of isothermal magnetic curves allowed the calculation of magnetic entropy change (?SM). Although the peak value of |?SM| is relatively low, ~1.1 J/(kg*K), it is very broad. The adiabatic temperature change (?T) measured near RT is ~0.49K. Such result is irrespective of the magnetizing-demagnetizing cycle frequency which varied from 2/min to 10/min.

Documents disponibles

Format PDF

Pages : 2 p.

Disponible

  • Prix public

    10 €

  • Prix membre*

    7,50 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Magnetocaloric effect in Gd-doped Ni-Cu-Mn-Ga alloy.
  • Identifiant de la fiche : 30013071
  • Langues : Anglais
  • Source : 6th International Conference on Magnetic Refrigeration at Room Temperature (Thermag VI). Proceedings: Victoria, Canada, September 7-10, 2014.
  • Date d'édition : 07/09/2014

Liens


Voir d'autres communications du même compte rendu (78)
Voir le compte rendu de la conférence