Document IIF
Effets de la mauvaise distribution de l'air sur la performance d'une pompe à chaleur air-eau sous des conditions de givrage.
Effects of airflow maldistribution on the performance of an air-to-water heat pump under frosting conditions.
Auteurs : GONG J. Y., YUAN X. L., HU W. X., et al.
Résumé
The effects of airflow maldistribution on the performance of an air-to-water heat pump system under frosting conditions were investigated experimentally. Different airflow distributions were experimented on a 50 kW unitary air-to-water heat pump. The results indicated that the airflow maldistribution was the dominant factor leading to the hunting of the thermostatic expansion valve for medium and/or large size finned tube evaporators. In stable stage, with airflow maldistribution degree (AMD) increasing, frosting was quickened and the system stable working time was shortened. The refrigeration system operating characteristics were lowered accordingly. The authors found the phenomenon seemed to be related to both the difference of refrigerant outlet temperature superheat and the frosting velocity. In hunting stage, with AMD increasing, the heat pump system pertinent performance data (suction pressure, evaporation temperature, discharge pressure, refrigerant outlet temperature, etc.) were degraded more dramatically.
Documents disponibles
Format PDF
Pages : ICR07-E2-1618
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effects of airflow maldistribution on the performance of an air-to-water heat pump under frosting conditions.
- Identifiant de la fiche : 2008-0860
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Experimental study of interaction between frost...
- Auteurs : GUO X., YANG B., WANG W., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Study on performance of a heat pump water heate...
- Auteurs : CAO F., FEI J., XING Z., et al.
- Date : 10/2009
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 29 - n. 14-15
Voir la fiche
-
Givrage sur un tube circulaire sous des conditi...
- Auteurs : YOON S. H., CHO K., CHO H. G., et al.
- Date : 19/03/2009
- Langues : Coréen
- Source : 3e Congrès coréen du froid.
Voir la fiche
-
Frost retardation of an air-source heat pump by...
- Auteurs : BYUN J. S., LEE J., JEON C. D.
- Date : 03/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 2
- Formats : PDF
Voir la fiche
-
Performance of a heat pump type air conditioner...
- Auteurs : LIU Y., WANG F., WANG T., et al.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche