Document IIF
Effets de la mauvaise distribution de l'écoulement d'air sur la performance d'un meuble de vente frigorifique ouvert.
Effects of the airflow maldistribution on the performance of an open refrigerated display cabinet.
Numéro : pap. 157
Auteurs : ROSSETTI A., MINETTO S., MARINETTI S.
Résumé
Airflow maldistribution in heat exchangers and air channels is a common problem in air conditioning and refrigeration systemsas it negatively affects heat transfer between the evaporator and the surrounding airflow. Furthermore, in the refrigeration field, temperature and velocity maldistribution downstream the evaporator can reach the discharge air grille (DAG), negatively influencing the heat removal from the exposed goods. The development of air maldistribution models, not only on the evaporator scale, but extended to the whole air circuit, might help in understanding and improving cooling isues.In the present paper the effects of the flow maldistribution in the air channel of an open refrigerated display cabinet is studied by means of computational fluid dynamics simulations. A fluid dynamic isothermal model based on experimental boundary conditions and validated by comparison with PIV measurements is presented. Due to the different geometrical scales, the evaporator is modeled using the equivalent resistance approach. The heat exchange process is then studied in a single fin model in order to assess the relationship between heat exchange coefficients, temperature and air velocity. Such a relationship is finally used in the governing equations, as an energy source term, and applied to the full channel model. This thermal fluid dynamic model allows to evaluate the effects of the maldistribution in terms of temperature, heat transfer coefficients, and cooling power. Discussion of the results is reported.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effects of the airflow maldistribution on the performance of an open refrigerated display cabinet.
- Identifiant de la fiche : 30012014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Date d'édition : 23/06/2014
Liens
Voir d'autres communications du même compte rendu (87)
Voir le compte rendu de la conférence
-
Impact of environmental conditions on the perfo...
- Auteurs : HEIDINGER G. G., NASCIMENTO S. M., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
A simplified thermal CFD approach to fins and t...
- Auteurs : ROSSETTI A., MINETTO S., MARINETTI S.
- Date : 09/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 57
- Formats : PDF
Voir la fiche
-
Improvement of air distribution in refrigerated...
- Auteurs : GRAY I., LUSCOMBE P., MCLEAN L., et al.
- Date : 08/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 5
- Formats : PDF
Voir la fiche
-
An experimental and computational study of appr...
- Auteurs : YASHAR D. A., DOMANSKI P. A., CHO H. H.
- Date : 02/2011
- Langues : Anglais
- Source : HVAC&R Research - vol. 17 - n. 1
Voir la fiche
-
Interactions between the environment and open r...
- Auteurs : TASSOU S. A., XIANG W.
- Date : 2003
- Langues : Anglais
- Source : ASHRAE Transactions. 2003 Winter Meeting, Chicago, Illinois. Volume 109, part 1 + CD-ROM.
Voir la fiche