Document IIF
Enquête sur l'amélioration potentielle des systèmes frigorifiques commerciaux au R744 basée par des concepts de destruction exergétique évitable et inévitable.
Potential enhancement investigation of commercial R744 refrigeration systems based on avoidable and unavoidable exergy destruction concepts.
Numéro : pap. 1041
Auteurs : GULLO P., CORTELLA G., MINETTO S.
Résumé
In this paper, the actual feasible reduction in the inefficiencies occurring in two different commercial CO2 refrigeration systems was evaluated. The analysis was based on the calculation of the avoidable and unavoidable irreversibilities taking place in their components. The systems under investigation, which were a R744 refrigeration system with parallel compression and a R744 refrigerating plant with dedicated mechanical subcooling, were assessed by taking into account the design outdoor temperature of 30 °C. A cooling capacity of 100 kW and an evaporating temperature of -10 °C were selected, while the global efficiencies of all the
chosen compressors were obtained by using some manufacturers’ selection software. The results revealed that, in both the selected cases, over 60% of the irreversibilities could be brought down. In particular, the inefficiencies of all the compressors were almost totally avoidable, whereas only half of the exergy destruction related to both the gas coolers and the evaporators could be actually reduced. The auxiliary compressor and the subcooling loop were accountable for14.6% and 25% of the total avoidable inefficiencies associated with their corresponding cycles.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Potential enhancement investigation of commercial R744 refrigeration systems based on avoidable and unavoidable exergy destruction concepts.
- Identifiant de la fiche : 30019111
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Date d'édition : 21/08/2016
- DOI : http://dx.doi.org/10.18462/iir.gl.2016.1041
Liens
Voir d'autres communications du même compte rendu (140)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : Système frigorifique; Exergie; R744; Supermarché; Sous-refroidissement; Performance; Compresseur
-
Current limits of CO2 compressors wo...
- Auteurs : NEBOT-ANDRÉS L., SÁNCHEZ D., CABELLO R., CALLEJA-ANTA D., FOSSI C., LLOPIS R.
- Date : 09/2021
- Langues : Anglais
- Source : 12th International Conference on Compressors and their Systems
- Formats : PDF
Voir la fiche
-
Supermarket application. Effects of sub-cooling...
- Auteurs : MAZZOLA D., SHEEHAN J., BORTOLUZZI D., et al.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Investigation of heat recovery in CO2 transcrit...
- Auteurs : SAWALHA S.
- Date : 01/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
Voir la fiche
-
Experimental COP enhancement of a CO2 transcrit...
- Auteurs : ARANGUREN P., SÁNCHEZ D., CASI A., ARAIZ M., ASTRAIN D., CABELLO R.
- Date : 11/11/2020
- Langues : Espagnol
- Source : X Congreso Ibérico y VIII Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2020.
- Formats : PDF
Voir la fiche
-
Transcritical CO2 commercial refrige...
- Auteurs : CORTELLA G., D'AGARO P., COPPOLA M. A.
- Date : 03/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 111
- Formats : PDF