Résumé
The distribution uniformity of refrigerant flow with phase change in parallel flat tubes is very important to the performance of heat exchangers. However, the existing predictions differ from the experimental data. The authors' review shows that the distribution uniformity of air flow and refrigerant flow in parallel flat tubes is greatly affected by working condition, structure, and fluid flow feature. It is suggested that the future research on the uniformity of both air flow distribution and refrigerant flow distribution in parallel flat tubes should be carried out to improve the performance of heat transfer in microchannel heat exchangers.
Documents disponibles
Format PDF
Pages : pp. 39-45
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2010-1807
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 31 - n. 6
- Date d'édition : 12/2010
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2010.06.039
Liens
Voir d'autres articles du même numéro (10)
Voir la source
Indexation
-
A critical assessment of two-phase flow distrib...
- Auteurs : PANGHAT K., MEHENDALE S. S.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental study of two-phase adiabatic flow ...
- Auteurs : POGGI F., MACCHI-TEJEDA H., MARECHAL A., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Boiling nucleation and two-phase flow patterns ...
- Auteurs : LI J., PETERSON G. P.
- Date : 11/2005
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 48 - n. 23-24
Voir la fiche
-
Modeling refrigerant maldistribution in microch...
- Auteurs : ZOU Y., TUO H., HRNJAK P. S.
- Date : 03/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 64 - n. 1-2
Voir la fiche
-
Two-phase refrigerant distribution in a paralle...
- Auteurs : KIM N. H., HAM J. H., KIM D. Y.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF