Étude de cas d'un système de refroidissement adiabatique indirect dans un immeuble historique.
Case study of indirect adiabatic cooling system in historical building.
Numéro : pap. 540
Auteurs : BRAHMANIS A., LESINSKIS A., KRUMINS A.
Résumé
The objective of the present study is to investigate the efficiency of indirect adiabatic chiller-based cooling system efficiency dependence on outdoor air humidity. The system is located in a historical building, in the temperate climate of Latvia. The data about electricity consumption, water consumption, chiller operation stages, average cooling temperatures, and outdoor air parameters have been acquired for the period of 2,5 months, during the cooling season. Using data collected by BACnet based BMS controllers and adiabatic chiller control system, we have analyzed operation efficiency of the chiller and its dependence on outdoor air humidity. Data range for the period from 1st August till 13th of October, year 2011 was taken for deeper analysis, which showed that in the 22.0±0.5°C temperature range for the studied period of time chiller’s COP is slightly dependent on outdoor air moisture.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Case study of indirect adiabatic cooling system in historical building.
- Identifiant de la fiche : 30009341
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Equipements d'humidification/déshumidification
- Mots-clés : Immeuble; Lettonie; Température; Rendement; Refroidisseur; Système évaporatif; Humidité; Conditionnement d'air; Climat
-
Étude de l'impact du climat sur le conditionnem...
- Auteurs : XIA Q., HUANG X., YIN Q.
- Date : 12/2012
- Langues : Chinois
- Source : Refrigeration - vol. 31 - n. 4
Voir la fiche
-
Evaluation of solid-desiccant-based evaporative...
- Auteurs : JAIN S., DHAR P. L., KAUSHIK S. C.
- Date : 06/1995
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 18 - n. 5
- Formats : PDF
Voir la fiche
-
Evaporative cooling pads: test procedure and ev...
- Auteurs : KOCA R. W., HUGHES W. C., CHRISTIANSON L. L.
- Date : 1991
- Langues : Anglais
- Source : Appl. Eng. Agric. - vol. 7 - n. 4
Voir la fiche
-
Peak load shaving by indirect evaporative cooli...
- Auteurs : NIELSEN G.
- Date : 04/12/2013
- Langues : Anglais
- Source : 44th International HVAC&R Congress and Exhibition.
- Formats : PDF
Voir la fiche
-
Analyse et vérification de l'efficacité de refr...
- Auteurs : WANG W., HUANG X., SUN T., et al.
- Date : 01/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 273
- Formats : PDF
Voir la fiche