Résumé
Despite the fact that an absorption refrigerator is required to improve its efficiency, even the design method of the absorption cycle has not been fully investigated. This research discusses the optimum design method of a double-effect absorption refrigerator, which has spread generally. The objects of the analysis are three typical double-effect absorption flows - series, reverse and parallel flow. COP is the evaluation function. As the analysis technique, the exterior point penalty function method, which can analyze nonlinear optimization problems with constraints, and the success and failure method are adopted to find out the optimum point. As a result, optimum COP for each flow was derived. For example, at the point of 80% temperature efficiency, it was 1.35, 1.37 and 1.40 for the series, reverse and parallel flow respectively.
Documents disponibles
Format PDF
Pages : ICR07-E2-1007
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Study on optimum design method of absorption refrigerator. 2. Application to double effect absorption cycle.
- Identifiant de la fiche : 2008-0639
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Conception; Système à absorption; Système biétage; Simulation; Optimisation; Modélisation; Eau-bromure de lithium
-
Theoretical analysis and optimization of a doub...
- Auteurs : XU G. P., DAI Y. Q., TOU K. W., TSO C. P.
- Date : 22/09/1996
- Langues : Anglais
- Source : Heat pumping technologies towards the next century: applications and markets. Proceedings of the 5th IEA Conference.
Voir la fiche
-
Thermo-economic evaluation and optimization of ...
- Auteurs : MISRA R. D., SAHOO P. K., GUPTA A.
- Date : 05/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 3
- Formats : PDF
Voir la fiche
-
Simulation of a double-effect vapour recompress...
- Auteurs : LUDOVISI D., WOREK W. M., MECKLER M.
- Date : 15/09/2001
- Langues : Anglais
- Source : CLIMA 2000. 7th REHVA World Congress, Naples 2001 [CD-ROM + Hard-copy abstracts].
Voir la fiche
-
Dynamic simulation of a double-effect parallel-...
- Auteurs : LIN P., WANG R. Z., WU J. Y.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
Intermediate pressure optimum mathematical calc...
- Auteurs : HE J., WANG D., YAN L.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche