A defrosting control method based on the optimal average performance of an air source heat pump (ASHP) unit is presented. The deterioration point of an ASHP unit is selected as the defrosting initiation criterion. To verify the feasibility and applicability of the defrosting control method based on the optimal average performance, a test apparatus was established in the sychrometric rooms and the defrosting characteristics of an ASHP unit was investigated experimentally for four: different defrosting initiation criteria under different frosting conditions. The frost thickness on the fins, the transient input power and heating capacity were measured. Based on the experimental results, the total heating capacity, total power consumption in the whole frosting/ defrosting cycles and average COP of the ASHP unit were analyzed. The experimental results indicated that when the deterioration point of the ASHP unit is selected as the defrosting initiation criterion, the average COP in the whole frosting/ defrosting cycles is the maximum, which confirmed that this defrosting initiation criterion is feasible and can be used for the optimal defrosting control of an ASHP unit.
Documents disponibles
Format PDF
Pages : 17-21
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30019657
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 37 - n. 169
- Date d'édition : 06/2016
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2016.03.017
Liens
Voir d'autres articles du même numéro (5)
Voir la source
-
Control strategy and experimental study on a no...
- Auteurs : LIANG C. H., ZHANG X. S., LI X. W., et al.
- Date : 06/2010
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 8-9
Voir la fiche
-
A novel Temperature-Humidity-Time defrosting co...
- Auteurs : ZHU J., SUN Y., WANG W., et al.
- Date : 06/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 54
- Formats : PDF
Voir la fiche
-
Less pumping means cooler ground loops.
- Auteurs : KAVANAUGH S.
- Date : 07/2011
- Langues : Anglais
- Source : ASHRAE Journal - vol. 53 - n. 7
Voir la fiche
-
Performance evaluation of air source heat pump ...
- Auteurs : LIU J., SUN Y., WANG W., et al.
- Date : 02/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
Voir la fiche
-
Experimental study of a control strategy for a ...
- Auteurs : QU M., FAN Y., LI T., et al.
- Date : 05/01/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 110