Une nouvelle méthode de régulation de la température, de l'humidité et de la durée du dégivrage basée sur une cartographie du givrage pour des pompes à chaleur aérothermiques.
A novel Temperature-Humidity-Time defrosting control method based on a frosting map for air-source heat pumps.
Résumé
To improve the defrosting accuracy and the energy efficiency of the air-source heat pump (ASHP) under frosting and defrosting conditions, a novel Temperature-Humidity-Time (T-H-T) defrosting control method, based on a frosting map for the ASHP unit, is proposed in this paper. A field test was conducted for two heating seasons, to verify the feasibility and applicability of the T-H-T method. The advantages of the T-H-T method, compared to the conventional Temperature-Time (T-T) defrosting control method, are presented. In total, eight cases are shown in this paper. Cases 1 to 4 were chosen to reveal the T-H-T performance under different frosting conditions. It was found that no matter what kind of frosting conditions, defrosting was always initiated in a similar situation: ~90 % of the outdoor coil surface was covered by frost; the temperature difference between the compressor suction and discharge increased by ~20 %; and the heating capacity decreased by ~30 %. These results indicate that the T-H-T method can make an accurate decision under different frosting conditions. Cases 5a, 5b and Cases 6a, 6b were two groups of cases to compare the advantages of the T-H-T method against the conventional T-T method. Cases 5a and 5b were chosen for the non-frosting condition. It was found that the T-T method initiated the defrosting operation 31 times within 24 hours. However, none of the defrosting operations was conducted for the T-H-T method. Cases 6a and 6b were chosen to compare these two methods under consecutive and variable frosting conditions. For the T-T method, 37 % of the defrosting processes were found to be executed under conditions where defrosting was not necessary. However, for the T-H-T method, all the defrosting controls were found to be accurate and reasonable. These results indicated that the novel T-H-T method is suitable for the defrosting control of the ASHP, and has a more competitive performance than the conventional T-T method.
Documents disponibles
Format PDF
Pages : 45-54
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A novel Temperature-Humidity-Time defrosting control method based on a frosting map for air-source heat pumps.
- Identifiant de la fiche : 30014561
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 54
- Date d'édition : 06/2015
Liens
Voir d'autres articles du même numéro (14)
Voir la source
-
Étude de la méthode de régulation du dégivrage ...
- Auteurs : XING Z., GUO X., LI J.
- Date : 06/2016
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 37 - n. 169
- Formats : PDF
Voir la fiche
-
Control strategy and experimental study on a no...
- Auteurs : LIANG C. H., ZHANG X. S., LI X. W., et al.
- Date : 06/2010
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 8-9
Voir la fiche
-
Optimizing energy consumption of a water-loop v...
- Auteurs : YUAN S., GRABON M.
- Date : 04/2011
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 31 - n. 5
Voir la fiche
-
Evolution de la performance des PAC air-eau rév...
- Auteurs : LÓPEZ R.
- Date : 09/2012
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 102 - n. 1126
Voir la fiche
-
Efektywnosc powietrznych pomp ciepla.
- Auteurs : ZAKRZEWSKI B., ZLOCZOWSKA E., TUCHOWSKI W.
- Date : 04/2013
- Langues : Polonais
- Source : Chlodnictwo - vol. 48 - n. 4
Voir la fiche