Document IIF
Etude de la performance à charge partielle d'un système de conditionnement d'air (pompe à chaleur) de type split.
Investigation on part-load performance of multi-connected air-conditioning (heat pump) unit.
Auteurs : LU H. L., CHEN H. X., XIE J. L., et al.
Résumé
According to GB 50189-2005 Design standard for energy efficiency of public buildings, multi-connected air-conditioning (heat pump) unit (MAU) during 98.7% running time, works with part load of designed value, its performance, capacity and especially refrigerating consumed power are obviously different from the designed values, thus it is of great importance to investigate part load performance of a working MAU: SEER and IPLV both are two popular integrated index as international and national standards ARI 210/240-2006, GB/T 18837-2002 to evaluate such a property of MAU in certain degree, they however do not reflect completely practical part load performance of a working MAU, for example, EER of the unit and exact departure to designed condition. In this paper, various effects of different factors on part-load performance, IPLV and SEER are reviewed. Such factors are basically summarized and classified as five kinds: dynamic cooling load, part load rate of MAU, level of match and installation with the building, overall heat transfer coefficient of building envelope and geographical climate parameters. They couple each other and define part-load performance of MAU together; then a method is proposed to define only the actual condition and performance of a working MAU under partial load conditions: EER, part load rate and deviation of outdoor temperature with reference to the designed condition. Two tests on practical PLP of MAU were conducted in Beijing city and Wuhan city respectively, and the result proved the method effective.
Documents disponibles
Format PDF
Pages : ICR07-B2-675
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Investigation on part-load performance of multi-connected air-conditioning (heat pump) unit.
- Identifiant de la fiche : 2008-0383
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Mobile Klimageräte.
- Auteurs : FITZNER K., FINKE U.
- Date : 22/11/2006
- Langues : Allemand
- Source : DKV-Tagungsbericht 2006, Dresden.
Voir la fiche
-
Part load performance of multi-connected air-co...
- Auteurs : SHI W., ZHAO W., WANG B.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Model of a reversible heat pump for part load e...
- Auteurs : KINAB E., FAU A., MARCHIO D., et al.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche
-
Gas-Wärmepumpe im Feldtest: Messungen an einer ...
- Auteurs : NITSCHKE-KOWSKY P., SCHUMACHER T., LENHART W.
- Date : 30/09/2005
- Langues : Allemand
- Source : CCI.Print - vol. 39 - n. 11
- Formats : PDF
Voir la fiche
-
NOUVELLES POMPES A CHALEUR A DEUX BLOCS AVEC FL...
- Auteurs : TOYODA A.
- Date : 1986
- Langues : Japonais
- Source : Refrigeration - vol. 61 - n. 709
Voir la fiche