Document IIF
Étude de la performance de cycles de Kalina pour la cogénération de froid.
Performance investigation of Kalina cooling cogeneration cycles.
Auteurs : SHANKAR R., SRINIVAS T.
Type d'article : Article, Article de la RIF
Résumé
The power and cooling demands are increasing drastically with increase in living stands and population. Kalina cycle system (KCS) is a power cycle and vapor absorption refrigeration (VAR) is a refrigeration cycle operating with zeotropic mixture. In this work, the common features of KCS and VAR are identified and developed a new Kalina cooling cogeneration cycle (KCCC) to generate combined power and cooling from a single plant configuration. The total output from cogeneration is compared with the total generation from the individual plants (KCS and VAR) at low temperature heat source (155-180°C). To justify the merit of proposed configuration, thermodynamic simulation has been conducted through critical investigation applied to flexible KCCC under varying operating conditions viz. strong solution concentration, source temperature, separator vapor concentration and dephlegmator effectiveness. The generated results are power, refrigeration, combined power and cooling, cycle energy utilization factor (ENUF) and plant ENUF. The power to total output ratio in KCCC once through cycle is considered as a reference to the other cooling cogenerations for the comparison. The highest cycle ENUF (0.39) is resulted with KCCC once through cycle. KCCC split cycle is not recommended because of its lower efficiency (0.18) compared to the non-integrated efficiency (0.21).
Documents disponibles
Format PDF
Pages : 163-185
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance investigation of Kalina cooling cogeneration cycles.
- Identifiant de la fiche : 30023140
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 86
- Date d'édition : 02/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.11.019
Liens
Voir d'autres articles du même numéro (42)
Voir la source
Indexation
-
Exergy-analysis based comparative study of abso...
- Auteurs : LI Y., HU R.
- Date : 25/01/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 93
Voir la fiche
-
A novel flexible multi-effect absorption system...
- Auteurs : MUGDADI B., AL-NIMR M.
- Date : 03/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 147
- Formats : PDF
Voir la fiche
-
Comparison of a new designed resorption refrige...
- Auteurs : GRUND M., HESSE U., WEIMER T., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Performance study of a solar absorption power-c...
- Auteurs : MUYE J., AYOU D. S., SARAVANAN R., et al.
- Date : 25/03/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 97
Voir la fiche
-
Optimized control strategy of a combined heatin...
- Auteurs : SCHICKTANZ M., RAJGOPAL N. K. K., NEUMANN H., et al.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche