Étude expérimentale concernant l'évolution des profils de température à l'intérieur d'une tour de refroidissement humide sous conditions de vent de travers.
Experimental study regarding the evolution of temperature profiles inside wet cooling tower under crosswind conditions.
Résumé
Based on similarity theory, this research details a thermal-state model experiment, concerning the evolution of the air/water temperature profiles inside a Natural Draft Wet Cooling Tower (NDWCT) under windless and crosswind conditions. Prior studies have shown that the air/water temperature distribution is fairly uniform and stable under windless (stagnant) conditions, but the uniformity is destroyed in the presence of windy conditions, and the air/water temperature of different points displays a large variation subject to the same crosswind velocity. Generally speaking, the highest air/water temperature values inside the whole tower lie on the windward and leeward direction, but the highest air temperature at the tower outlet appears near the leeward side zone, rather than exactly on the leeward side. Based on this research, the air/water temperature profiles regarding measurement of values can be obtained accurately under windless and crosswind conditions, a fact that can help confirm the specific location of vortex on the windward and leeward side. All of above findings can provide an important theoretical foundation concerning further research, specifically for energy-saving aspects NDWCTs.
Détails
- Titre original : Experimental study regarding the evolution of temperature profiles inside wet cooling tower under crosswind conditions.
- Identifiant de la fiche : 30012369
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 86
- Date d'édition : 12/2014
- DOI : http://dx.doi.org/10.1016/j.ijthermalsci.2014.07.010
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
-
Influence of non-uniform layout fillings on the...
- Auteurs : GAO M., ZHANG L., WANG N. N., et al.
- Date : 25/01/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 93
Voir la fiche
-
ANALYSIS OF COOLING TOWER PERFORMANCE ENHANCEMENT.
- Auteurs : SCALABRIN G.
- Date : 24/08/1987
- Langues : Anglais
- Source : Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Saving energy with cooling towers.
- Auteurs : MORRISON F.
- Date : 02/2014
- Langues : Anglais
- Source : ASHRAE Journal - vol. 56 - n. 2
Voir la fiche
-
Thermal and chemical analysis of fouling phenom...
- Auteurs : WU X., CREMASCHI L.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Entransy analysis on the performance of the cou...
- Auteurs : ZHU Y., ZHANG K., LIU J., et al.
- Date : 02/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 98
- Formats : PDF
Voir la fiche