Résumé
Membrane-based liquid desiccant dehumidification has attracted increasing interests with elimination of solution droplets carryover problem. In this study, a membrane-based hybrid liquid desiccant dehumidification cooling system is developed, which is mainly composed of a dehumidifier, a regenerator and an evaporative cooler. The system is capable to remove latent load by the liquid desiccant dehumidification unit and simultaneously to handle sensible load with an evaporative cooling unit. This paper presents a performance evaluation study of the hybrid system with calcium chloride as liquid desiccant based on experimental data. Series of tests are conducted to identify influences of operating variables and conditions (i.e. desiccant solution concentration ratio, regeneration temperature, inlet air condition, etc.) on the system performance. The experimental results indicate that the system is viable for dehumidification cooling purpose. Furthermore, it is noteworthy that mass balance between the dehumidifier and regenerator should be achieved for system steady operation. Thermal COPth of 0.70 and electrical COPel of 2.62 are achieved respectively under steady operating condition at CaCl2 concentration ratio of 36%.
Détails
- Titre original : Experimental study of a membrane-based dehumidification cooling system.
- Identifiant de la fiche : 30021189
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 115
- Date d'édition : 25/03/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.10.153
Liens
Voir d'autres articles du même numéro (31)
Voir la source
Indexation
- Thèmes : Equipements d'humidification/déshumidification
- Mots-clés : Déshumidification; Liquide; Régénération; Membrane; Experimentation; Déshydratant; COP
-
Comparative analysis of vacuum membrane distill...
- Auteurs : ZHOU J., ZHANG X.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Photovoltaic capacitive deionization regenerati...
- Auteurs : YANG Q., LI X. W., FANG A. M.
- Date : 05/05/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 117
Voir la fiche
-
Modeling of a flat plate membrane-distillation ...
- Auteurs : RATTNER A. S., NAGAVARAPU A. K., GARIMELLA S., et al.
- Date : 07/2011
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 54 - n. 15-16
Voir la fiche
-
Experimental investigation of a hybrid liquid d...
- Auteurs : FLEIG D., VÖLKER L., MATTHES J., et al.
- Date : 07/08/2017
- Langues : Anglais
- Source : International sorption heat pump conference, ISHPC 2017, Tokyo august 7-10.
Voir la fiche
-
Méthodes de régénération pour un système de con...
- Auteurs : LI H., ZHANG T., CONG L., et al.
- Date : 11/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 284
- Formats : PDF
Voir la fiche