Document IIF
Étude expérimentale du R-152a comme frigorigène alternatif au R-134a dans les réfrigérateurs domestiques.
R-152a as an alternative refrigerant to R-134a in domestic refrigerators: An experimental analysis.
Auteurs : MAIORINO A., APREA C., DEL DUCA M. G., et al.
Type d'article : Article, Article de la RIF
Résumé
Among all sectors of refrigeration, one of the most affected by the latest international regulations is the domestic refrigeration. Although for it has been suggested some solutions, such as the construction of household refrigerator operating with the hydrocarbons, there remains the need to find a substitute for R-134a. With the aim of finding a simple implementation solution, in the present work, it is reported an experimental investigation carried out on a domestic no-frost refrigerator designed and built to operate with R-134a and for which a drop-in with R-152a has been realised. Different tests have been performed with the aim to identify the right charge of R-152a too. In line with the standard ISO 15502:2005 (2005), pull-down and 24 h energy consumption experiments have been run to evaluate the performance of R-152a as the drop-in replacement of R-134a in a domestic refrigerator. Also, a theoretical model has been proposed with the aim to give support to the observed energy change.
Documents disponibles
Format PDF
Pages : 106-116
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : R-152a as an alternative refrigerant to R-134a in domestic refrigerators: An experimental analysis.
- Identifiant de la fiche : 30025232
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
- Date d'édition : 12/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.09.020
Liens
Voir d'autres articles du même numéro (20)
Voir la source
Indexation
-
R152a versus R134a in domestic refrigerator-fre...
- Auteurs : SANVORDENKER K. S.
- Date : 14/07/1992
- Langues : Anglais
Voir la fiche
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Energy efficiency of HFC134a versus HFC152a.
- Auteurs : VINEYARD E. A., SWATKOWSKI L. J. Jr
- Date : 20/10/1993
- Langues : Anglais
- Source : The 1993 International CFC and Halon Alternatives Conference. Stratospheric Ozone Protection for the 90's. Proceedings.
Voir la fiche
-
Environmental impact assessment of R-152a as a ...
- Auteurs : MAIORINO A., LLOPIS R., DEL DUCA M. G., APREA C.
- Date : 09/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Formats : PDF
Voir la fiche