Résumé

The cross-flow fan is an essential component of an air-conditioner indoor unit, and its aerodynamic performance seriously affects the performance and heat exchange efficiency of air-conditioning. The internal flow of the cross-flow fan is studied by PIV measurements combined with the three-dimensional unsteady simulation. It is observed that the internal flow of the cross-flow fan is unevenly distributed along the axial direction, and it presents prominent three-dimensional characteristics. Due to the influence of the end-wall, the eccentric vortex is strong in the middle and weak at both ends. Therefore, a pressure gradient along the axial direction in the eccentric vortex area, resulting in axial fluid transport inside the eccentric vortex. At the exit of the impeller, there is a small recirculation zone near the end-wall, which grows continually as it moves downstream in the diffuser section, thereby blocking the outlet. This paper further proposes a structure optimization, which effectively enhances the eccentric vortex near the end-wall and reduces the recirculation zone in the diffuser section, resulting in a 2.1% increase in the flow rate of air-conditioner indoor unit and a 0.8dB reduction in noise level. It is indicated that the structure optimization strategy based on the understanding of three-dimensional flow is beneficial to the internal flow and effectively improves the aerodynamic performance and the aeroacoustics performance of the whole air-conditioner indoor unit.

Documents disponibles

Format PDF

Pages : 102-111

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental and numerical study of cross-flow fan in air-conditioner indoor unit.
  • Identifiant de la fiche : 30030151
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 141
  • Date d'édition : 09/2022
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.05.020