Etude expérimentale sur la régulation de l'écoulement du courant continu dans un système frigorifique à tube à pulsation monoétagé fonctionnant à des températures inférieures à 20 K.

Experimental investigation on DC flow control in a single-stage pulse tube refrigerator operating below 20 K.

Résumé

An experimental investigation on a single-stage pulse tube refrigerator operating below 20 K is undertaken. The influence of DC flow induced by he introduction of double-inlet on the refrigeration performance of the cooler is experimentally examined. With effective control of DC flow, 18.4 and 14.7 K minimum temperatures have been reached driven by RW2 and CP4000 compressor respectively, and 11.5 and 29.5 W cooling-power at 30 K are obtained.

Détails

  • Titre original : Experimental investigation on DC flow control in a single-stage pulse tube refrigerator operating below 20 K.
  • Identifiant de la fiche : 2006-1037
  • Langues : Anglais
  • Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
  • Date d'édition : 22/04/2003