Impact de la résistance à l'écoulement d'un régénérateur sur la stabilité d'un refroidisseur à tube à pulsation.

Influence of regenerator flow resistance on stability of pulse-tube cooler.

Résumé

The induced DC flow by introduction of the double-inlet in a pulse tube cooler is the key point causing temperature instability. The possibility of utilizing regenerator flow resistance to suppress DC flow is theoretically and experimentally investigated. Both results show that with a proper larger regenerator flow resistance, DC flow could be suppressed to a smaller extent. Then a long-time operation of the cooler with a stable temperature output at 80 K temperature region could be carried out.

Détails

  • Titre original : Influence of regenerator flow resistance on stability of pulse-tube cooler.
  • Identifiant de la fiche : 2006-1036
  • Langues : Anglais
  • Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
  • Date d'édition : 22/04/2003

Liens


Voir d'autres communications du même compte rendu (166)
Voir le compte rendu de la conférence