Etude expérimentale sur les nouveaux mélanges frigorigènes destinés à remplacer le R12 dans les réfrigérateurs domestiques.

Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators.

Auteurs : TASHTOUSH B., TAHAT M., SHUDEIFAT M. A.

Type d'article : Article

Résumé

An experimental study on the replacement of R12 in domestic refrigerators by new hydrocarbon/hydrofluorocarbon refrigerant mixtures has been carried out. The results show that butane/propane/R134a mixtures provide excellent performance parameters, such as COP of refrigerator, compression power, volumetric efficiency, condenser duty, compressor discharge pressure and temperature, relative to a 210 g charge of R12. In addition, there is no need to change the compressor lubricating oil used with R12.

Détails

  • Titre original : Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators.
  • Identifiant de la fiche : 2002-2920
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 22 - n. 5
  • Date d'édition : 04/2002

Liens


Voir d'autres articles du même numéro (1)
Voir la source