Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators.

Author(s) : TASHTOUSH B., TAHAT M., SHUDEIFAT M. A.

Type of article: Article

Summary

An experimental study on the replacement of R12 in domestic refrigerators by new hydrocarbon/hydrofluorocarbon refrigerant mixtures has been carried out. The results show that butane/propane/R134a mixtures provide excellent performance parameters, such as COP of refrigerator, compression power, volumetric efficiency, condenser duty, compressor discharge pressure and temperature, relative to a 210 g charge of R12. In addition, there is no need to change the compressor lubricating oil used with R12.

Details

  • Original title: Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators.
  • Record ID : 2002-2920
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 22 - n. 5
  • Publication date: 2002/04

Links


See other articles in this issue (1)