Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators.
Author(s) : TASHTOUSH B., TAHAT M., SHUDEIFAT M. A.
Type of article: Article
Summary
An experimental study on the replacement of R12 in domestic refrigerators by new hydrocarbon/hydrofluorocarbon refrigerant mixtures has been carried out. The results show that butane/propane/R134a mixtures provide excellent performance parameters, such as COP of refrigerator, compression power, volumetric efficiency, condenser duty, compressor discharge pressure and temperature, relative to a 210 g charge of R12. In addition, there is no need to change the compressor lubricating oil used with R12.
Details
- Original title: Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators.
- Record ID : 2002-2920
- Languages: English
- Source: Applied Thermal Engineering - vol. 22 - n. 5
- Publication date: 2002/04
Links
See other articles in this issue (1)
See the source
Indexing
-
Hydrocarbons instead of CFCs in household refri...
- Author(s) : NOVOTEL'NOV V. N., BODIO E., VIL'CHEK M., HOROVSKIJ M.
- Date : 1994/09
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 5
View record
-
Pure hydrocarbons as refrigerants in household ...
- Author(s) : MEYER A.
- Date : 1993/02
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 46 - n. 2
View record
-
Working parameters of domestic refrigerators fi...
- Author(s) : BODIO E., CHOROWSKI M., WILCZEK M.
- Date : 1993/09
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 16 - n. 5
- Formats : PDF
View record
-
The use of hydrocarbon mixtures as refrigerants...
- Author(s) : HAMMAD M. A., ALSAAD M. A.
- Date : 1999/11
- Languages : English
- Source: Applied Thermal Engineering - vol. 19 - n. 11
View record
-
Measurements on household refrigerators with co...
- Author(s) : JURGENSEN H.
- Date : 1993/02
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 46 - n. 2
View record