Etude expérimentale sur un système frigorifique quadri-étagé à auto-cascade avec des températures descendant jusqu'à -150 °C.

Experimental study on a four-stage auto-cascade refrigeration system with the temperature down to -150°C.

Auteurs : XIAO C. J., ZHANG H., LIU H. S., et al.

Résumé

A four-stage auto-cascade refrigeration cycle is developed and the experimental rig is set up. The blend of refrigerants used was a mixture of R600a/R23/R14/R740. The reasonable proportion of the blend refrigerants is determined. The temperature in the centre of the freezer decreases successfully down to -150°C. Refrigerant temperatures after throttling were tested and analysed. The effect of the proportion of the blend refrigerants on the refrigeration temperature is concluded.

Détails

  • Titre original : Experimental study on a four-stage auto-cascade refrigeration system with the temperature down to -150°C.
  • Identifiant de la fiche : 2009-0097
  • Langues : Anglais
  • Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
  • Date d'édition : 05/04/2008

Liens


Voir d'autres communications du même compte rendu (170)
Voir le compte rendu de la conférence