ETUDE NUMERIQUE D'UNE CONDUITE ENTERREE TRANSPORTANT DU GAZ A DES TEMPERATURES INFERIEURES A 273 K (0 DEG C). COMPARAISON DE PLUSIEURS MODELES AVEC UNE EXPERIENCE PILOTE.

NUMERICAL STUDY OF A BURIED GAS PIPE AT NEGATIVE TEMPERATURE. COMPARISON OF SEVERAL MODELS WITH A PILOT EXPERIMENT.

Résumé

CETTE COMMUNICATION PRESENTE LES RESULTATS D'UNE COMPARAISON ENTRE PLUSIEURS MODELES DECRIVANT LE COMPORTEMENT THERMIQUE D'UN SOL AUTOUR D'UNE CONDUITE FROIDE ENTERREE AINSI QUE LA CONFRONTATION DE CALCULS AVEC DES MESURES FAITES EN STATION PILOTE. UN MODELE THERMIQUE BIDIMENSIONNEL DE REGIME PERMANENT SERT A DETERMINER LA POSITION D'EQUILIBRE DE L'ISOTHERME 273K (0 DEG C) SANS TENIR COMPTE DU CHANGEMENT DE PHASE. UN MODELE UNIDIMENSIONNEL AXISYMETRIQUE TRAITE LE PROBLEME DE CHANGEMENT DE PHASE EN REGIME TRANSITOIRE ET S'AVERE TRES PRATIQUE POUR DECRIRE LE PHENOMENE DANS UN DOMAINE ETENDU DE CONDITIONS GEOMETRIQUES ET THERMIQUES. ENFIN, UN MODELE BIDIMENSIONNEL ELABORE SERT DE REFERENCE POUR DETERMINER LES LIMITES DU DOMAINE D'APPLICATION DU MODELE AXISYMETRIQUE.

Détails

  • Titre original : NUMERICAL STUDY OF A BURIED GAS PIPE AT NEGATIVE TEMPERATURE. COMPARISON OF SEVERAL MODELS WITH A PILOT EXPERIMENT.
  • Identifiant de la fiche : 1988-1672
  • Langues : Anglais
  • Date d'édition : 01/09/1986
  • Source : Source : Proc. int. Symp. Heat Mass Transf. Refrig. Cryog., Dubr.
    324-333; 3 fig.; 2 tabl.; 7 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Indexation