Étude numérique des performances opérationnelles d’une nouvelle pompe à chaleur aérothermique sans givre utilisant trois différents types de frigorigènes.
Numerical study on the operating performances of a novel frost-free air-source heat pump unit using three different types of refrigerant.
Résumé
Air-source heat pump (ASHP) is a promising device using in residential buildings because of its energy-savings. Besides, R134a and R407C as environmental friendly refrigerant have advantage to apply into heat pump system. In this study, an investigation of a novel frost-free ASHP system, integrated with dehumidification and thermal energy storage, working with R134a and R407C as an R22 alternative, was presented. A mathematical model of the system is constructed and verified by comparison with experimental data that shows the measured results are in good accordance with the numerical ones. According to the mathematical model, the dynamic performance of the system is characterized by dehumidification and regeneration efficiency, suction and discharge pressure, COP and so on at ambient temperature of 0°C and RH (relatively humidity) of 85%. The results show that the time for keeping the evaporator frost-free operation for R22, R407C and R134a are 29, 34 and 35 minutes, respectively. In addition, at the end of working time, the discharge pressure of compressor for R134a is 29 and 32% lower than that for R22 and R407C. What is more, at the given ambient temperature of -10°C and RH of 85%, the average COP for R134a is 3.3 and 8.6%, respectively, which is higher than that for R22 and R407C.
Détails
- Titre original : Numerical study on the operating performances of a novel frost-free air-source heat pump unit using three different types of refrigerant.
- Identifiant de la fiche : 30020757
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 112
- Date d'édition : 05/02/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.10.040
Liens
Voir d'autres articles du même numéro (39)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
HCFC;
HFC - Mots-clés : R407C; R134a; Givre; Comparaison; Système aérothermique; R22; Pompe à chaleur; Modélisation; Immeuble d'habitation; Évaporateur
-
Evaluation de la performance de systèmes à pomp...
- Auteurs : TAIRA S., YAZIMA R., TARUTANI I., et al.
- Date : 2001
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 1
Voir la fiche
-
A comparison of different generalised modelling...
- Auteurs : LEE C. K., LAM H. N.
- Date : 06/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 4
- Formats : PDF
Voir la fiche
-
Comparison of R407C and R410A with R22 in a 10....
- Auteurs : LINTON J. W., SNELSON W. K., HEARTY P. F., TRIEBE A. R., MURPHY F. T., LOW R. E., GILBERT B. E.
- Date : 23/07/1996
- Langues : Anglais
- Source : Proceedings of the 1996 Purdue International Refrigeration Conference.
Voir la fiche
-
Water-source heat pumps with HFC refrigerants.
- Auteurs : GLAMM P.
- Date : 03/1995
- Langues : Anglais
- Source : IEA HPC Newsl. - vol. 13 - n. 1
Voir la fiche
-
Improving robustness of transient heat exchange...
- Auteurs : MA J., KIM D., BRAUN J. E.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche