Résumé
This paper presents a swing compressor with no valves employed in air conditioning systems. The design and work principle of this swing compressor are introduced. Compared with the conventional swing compressor, this novel swing compressor has no discharge closed volume in structure and the adiabatic indicated efficiency is 98.5%. In addition, it is a new method to use centrifugal force to separate oil and refrigerant in the exhaust cavity and the reasonable design of the oil supply system allows this novel swing compressor with no valves to be employed in air conditioning system. Overall, this swing compressors with no valves has the advantages of light weight, simpler component geometries and more suitable for application in air conditioning.
Documents disponibles
Format PDF
Pages : 300-306
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Structural study on a swing compressor with no valves for air conditioning systems.
- Identifiant de la fiche : 30023541
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 88
- Date d'édition : 04/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.02.028
Liens
Voir d'autres articles du même numéro (57)
Voir la source
Indexation
- Thèmes : Compresseurs
- Mots-clés : Comparaison; Centrifugation; Soupape; Séparation; Huile; Frigorigène; Compresseur
-
R718 turbo chillers and vacuum ice generation -...
- Auteurs : HONKE M., SAFARIK M., HERZOG R.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Viscosimètre automatique.
- Auteurs : SHISHKIN Ju. P., RAZUMOV S. V.
- Date : 1992
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 6
Voir la fiche
-
Pressure to perform: air compressor companies f...
- Auteurs : FINNEGAN M.
- Date : 04/1998
- Langues : Anglais
- Source : CryoGas International - vol. 36 - n. 4
Voir la fiche
-
INFLUENCE DE LA FORCE DU GAZ ET DU GOMMAGE DE L...
- Auteurs : SHU P. C.
- Date : 12/1983
- Langues : Chinois
- Source : J. chin. Assoc. Refrig. - n. 4
Voir la fiche
-
The development of an advanced turbo compressor...
- Auteurs : ALLAM R. J., PIKE R. G.
- Date : 26/04/1994
- Langues : Anglais
- Source : Cryogenics '94. The third international conference.
Voir la fiche