Etudes en laboratoire de la performance de pompes à chaleur réversibles résidentielles au CO2 et au HCFC-22 : résultats préliminaires.

Laboratory experiments on the performance of CO2 and HCFC-22 reversible heat pumps for residential use: preliminary results.

Résumé

A CO2 prototype unit is compared to a conventional R22 unit, both in heating and cooling mode. The overall system efficiency of the CO2 system in terms of COP is competitive to that of the R22 system in both modes of operation. The CO2 heat exchanger design concept is described. Water retention has been a problem. The CO2 compressor has not performed optimally in some of the experiments, owing to poor lubrication. Considerable improvement in the CO2 system have to be made.

Documents disponibles

Format PDF

Document à numériser, disponible sous dix jours

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Laboratory experiments on the performance of CO2 and HCFC-22 reversible heat pumps for residential use: preliminary results.
  • Identifiant de la fiche : 1998-3764
  • Langues : Anglais
  • Source : Emerging trends in refrigeration and air-conditioning.
  • Date d'édition : 18/03/1998