Document IIF

Etudes sur une pompe à bulles fonctionnant avec un réfrigérateur à absorption de vapeur à deux fluides.

Studies on bubble pump operated two-fluid vapour absorption refrigerator.

Résumé

Air cooled absorber and condenser, and replacement of the solution pump by a heat operated bubble pump are necessary for miniaturisation of the vapour absorption water/lithium bromide refrigeration system, which is also capable of running exclusively on heat energy. Such a bubble pump is designed for a 50-watt cooling capacity using hydrostatic principle to maintain the required pressure drop between the system components. An evaporator temperature of 7.5 °C is obtained at no load condition and a refrigerating capacity of 30 watts is realized at 19 °C achieving an actual COP of 0.38 with source and sink temperatures of 85 and 40 °C respectively.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Studies on bubble pump operated two-fluid vapour absorption refrigerator.
  • Identifiant de la fiche : 2000-1334
  • Langues : Anglais
  • Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
  • Date d'édition : 19/09/1999

Liens


Voir d'autres communications du même compte rendu (447)
Voir le compte rendu de la conférence