Évaluation de la fiabilité et de la performance d'un conditionneur d'air utilisant un frigorigène à faible GWP.
Performance and reliability evaluation of a room air conditioner with low GWP refrigerant.
Numéro : pap. NS27
Auteurs : OKAZAKI T., MAEYAMA H., SAITO M., et al.
Résumé
The system performance of a room air conditioner (RAC) with low GWP refrigerants was evaluated. The test units are drop-in unit and modified unit with a rotary compressor and alkyl benzene oil. As test results, the rated cooling capacity (4.0 kW) can not be obtained and APF ratio of HFO-1234yf is 80% to R410A in drop-in test. In modified unit test, the rated cooling capacity can be obtained and APF ratio of HFO-1234yf is 91% to R410A. In the test using the modified compressor, APF ratio of HFO-1234yf is 95% to R410A. From these results, it is predicted that the size of indoor unit is 12% and the size of outdoor unit is 54% larger than R410A unit to obtain the same performance as R410A. Also, the system performance of R32/HFO-1234yf mixtures was evaluated. In R32/HFO-1234yf mixtures APF tends to increase in the range of more than 30wt% of R32 and APF ratio to R410A becomes 93% on condition that R32 concentration is 60wt%. Furthermore, stability and sliding characteristics were evaluated and compared with R410A results. HFO-1234yf is less stable than R410A. Especially, the air accelerates its deterioration severely. On the other hand, HFO-1234yf has better sliding property than R410A.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance and reliability evaluation of a room air conditioner with low GWP refrigerant.
- Identifiant de la fiche : 30000591
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Date d'édition : 17/02/2010
Liens
Voir d'autres communications du même compte rendu (75)
Voir le compte rendu de la conférence
Indexation
-
Application of low global warming potential ref...
- Auteurs : FUJITAKA A., SHIMIZU T., SATO S., et al.
- Date : 17/02/2010
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
Voir la fiche
-
Experimental study of low GWP refrigerants for ...
- Auteurs : HARA H., OONO M., IWATA I.
- Date : 17/02/2010
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
Voir la fiche
-
Drop-in performance of low GWP refrigerants in ...
- Auteurs : BARVE A., CREMASCHI L.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Évaluation de la performance du HC-600a comme f...
- Auteurs : OHNO K., KIMURA K., YAMAGUCHI S., et al.
- Date : 2013
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 30 - n. 4
Voir la fiche
-
Performance of an R-410A room air conditioner m...
- Auteurs : JANICKI C., HERMANN K., NEUMAN J., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche