Performance and reliability evaluation of a room air conditioner with low GWP refrigerant.
Number: pap. NS27
Author(s) : OKAZAKI T., MAEYAMA H., SAITO M., et al.
Summary
The system performance of a room air conditioner (RAC) with low GWP refrigerants was evaluated. The test units are drop-in unit and modified unit with a rotary compressor and alkyl benzene oil. As test results, the rated cooling capacity (4.0 kW) can not be obtained and APF ratio of HFO-1234yf is 80% to R410A in drop-in test. In modified unit test, the rated cooling capacity can be obtained and APF ratio of HFO-1234yf is 91% to R410A. In the test using the modified compressor, APF ratio of HFO-1234yf is 95% to R410A. From these results, it is predicted that the size of indoor unit is 12% and the size of outdoor unit is 54% larger than R410A unit to obtain the same performance as R410A. Also, the system performance of R32/HFO-1234yf mixtures was evaluated. In R32/HFO-1234yf mixtures APF tends to increase in the range of more than 30wt% of R32 and APF ratio to R410A becomes 93% on condition that R32 concentration is 60wt%. Furthermore, stability and sliding characteristics were evaluated and compared with R410A results. HFO-1234yf is less stable than R410A. Especially, the air accelerates its deterioration severely. On the other hand, HFO-1234yf has better sliding property than R410A.
Available documents
Format PDF
Pages: 7 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance and reliability evaluation of a room air conditioner with low GWP refrigerant.
- Record ID : 30000591
- Languages: English
- Source: Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Publication date: 2010/02/17
Links
See other articles from the proceedings (75)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
Thermodynamic measurements;
HFCs - Keywords: R410A; R1234yf; Air conditioner; Drop-in; R32; Performance; GWP; Refrigerant; Air conditioning
-
Application of low global warming potential ref...
- Author(s) : FUJITAKA A., SHIMIZU T., SATO S., et al.
- Date : 2010/02/17
- Languages : English
- Source: Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
View record
-
Experimental study of low GWP refrigerants for ...
- Author(s) : HARA H., OONO M., IWATA I.
- Date : 2010/02/17
- Languages : English
- Source: Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
View record
-
Performance of an R-410A room air conditioner m...
- Author(s) : JANICKI C., HERMANN K., NEUMAN J., et al.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Room air-conditioner performance characteristic...
- Author(s) : NAKANISHI M., MATSUDA K.
- Date : 2002/12/05
- Languages : Japanese
- Source: The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2002: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
View record
-
Assessment of environmentally friendly refriger...
- Author(s) : SHEN B., BANSAL P.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record