Document IIF
Évaluation de la performance annuelle des systèmes à pompe à chaleur géothermiques : une comparaison entre les systèmes à vitesse unique et à vitesse variable.
Evaluation of the annual performance of ground source heat pump systems: a comparison between single speed and variable speed systems.
Numéro : pap. ID: 843
Auteurs : MADANI H., LUNDQVIST P.
Résumé
In the present paper, modelling and simulation was carried out for a Ground Source Heat Pump (GSHP) system in the presence of all the most important interacting sub-systems such as building, ground heat source, electrical auxiliary heater, and the heat pump unit in order to make a fair and comprehensive comparison between the annual performance of on/off controlled and variable capacity systems. The annual modelling showed that dimensioning of the on/off controlled GSHP based on the peak heat demand of the building plays a significant role when two control strategies are compared: if the on/off controlled GSHP is dimensioned to cover only 57% of the peak heat demand of the building, the electrical auxiliary, which covers about 10% of the annual heating demand of the building, makes the SPF of the on/off controlled GSHP be lower than the one of the variable speed system. On the contrary, when the on/off controlled system is dimensioned to cover about 70% of the building’s peak heat demand, i.e. about 98% of the annual heat demand of the building, the SPF of the on/off controlled system can higher than the variable capacity systems.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Evaluation of the annual performance of ground source heat pump systems: a comparison between single speed and variable speed systems.
- Identifiant de la fiche : 30001830
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
-
Evaluation of a ground source heat pump system ...
- Auteurs : EDWARDS K. C., JONES A. T., FINN D. P.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Long-term model-based performance of ground hea...
- Auteurs : RUAN W., HORTON W. T.
- Date : 06/2011
- Langues : Anglais
- Source : HVAC&R Research - vol. 17 - n. 3
Voir la fiche
-
Energy efficiency in a ground source heat pump ...
- Auteurs : DEL COL D., BENASSI G., MANTOVAN M., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Theoretical study on dynamic characteristics of...
- Auteurs : PENG Y., WANG Z., ZHANG Z., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Etude sur les applications des refroidisseurs c...
- Auteurs : UEDA K., HASEGAWA Y., SHIMODA Y.
- Date : 07/2008
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 136
Voir la fiche