IIR document
Evaluation of the annual performance of ground source heat pump systems: a comparison between single speed and variable speed systems.
Number: pap. ID: 843
Author(s) : MADANI H., LUNDQVIST P.
Summary
In the present paper, modelling and simulation was carried out for a Ground Source Heat Pump (GSHP) system in the presence of all the most important interacting sub-systems such as building, ground heat source, electrical auxiliary heater, and the heat pump unit in order to make a fair and comprehensive comparison between the annual performance of on/off controlled and variable capacity systems. The annual modelling showed that dimensioning of the on/off controlled GSHP based on the peak heat demand of the building plays a significant role when two control strategies are compared: if the on/off controlled GSHP is dimensioned to cover only 57% of the peak heat demand of the building, the electrical auxiliary, which covers about 10% of the annual heating demand of the building, makes the SPF of the on/off controlled GSHP be lower than the one of the variable speed system. On the contrary, when the on/off controlled system is dimensioned to cover about 70% of the building’s peak heat demand, i.e. about 98% of the annual heat demand of the building, the SPF of the on/off controlled system can higher than the variable capacity systems.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Evaluation of the annual performance of ground source heat pump systems: a comparison between single speed and variable speed systems.
- Record ID : 30001830
- Languages: English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Publication date: 2011/08/21
Links
See other articles from the proceedings (569)
See the conference proceedings
Indexing
-
Evaluation of a ground source heat pump system ...
- Author(s) : EDWARDS K. C., JONES A. T., FINN D. P.
- Date : 2011/08/21
- Languages : English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
View record
-
Long-term model-based performance of ground hea...
- Author(s) : RUAN W., HORTON W. T.
- Date : 2011/06
- Languages : English
- Source: HVAC&R Research - vol. 17 - n. 3
View record
-
Energy efficiency in a ground source heat pump ...
- Author(s) : DEL COL D., BENASSI G., MANTOVAN M., et al.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Study on a non-condensing air-conditioning syst...
- Author(s) : TSAY Y. S., KATO S., OOKA R., et al.
- Date : 2007/09
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 126
View record
-
Performance comparison between enthalpy recover...
- Author(s) : TU R., LIU X. H., JIANG Y.
- Date : 2013/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 8
- Formats : PDF
View record