Evaluation de la performance des conditionneurs d'air au HC-290.
Performance assessment of air conditioners with HC-290.
Auteurs : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
Résumé
HCFC-22, widely used in room air conditioners, has to be phased out by 2030 under the Montreal Protocol. HC-290 is being considered as alternative to HCFC-22. A 5.13 kW capacity split air conditioner designed for HCFC-22 was considered. After establishing the baseline performance data with HCFC-22, the unit was retrofitted with HC-290. Under the drop-in test, the cooling capacity with HC-290 was lower by 6% and COP higher by 14%. The optimized charge of HC-290 was about 50% of HCFC-22 by weight. A 30% larger condenser gave 1.6% lower capacity and 10% higher COP. With a 10% higher capacity compressor, the cooling capacity was improved by 2.8% and COP was lower by 1.1%. In the case of 10% higher capacity compressor and 14.7% longer capillary, the cooling capacity was 5.2% higher with 2.9% lower COP. ORNL Heat Pump Design Model was used to predict the performance of the systems with HC-290 and to optimize the system.
Documents disponibles
Format PDF
Pages : 2010-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance assessment of air conditioners with HC-290.
- Identifiant de la fiche : 2010-1978
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Date d'édition : 12/04/2010
Liens
- Voir les traductions : Evaluación de las prestaciones de acondicionadores de aire con HC-290.
Valutazione delle prestazioni dei condizionatori d'aria funzionanti con HC 290 (propano).
Voir d'autres communications du même compte rendu (84)
Voir le compte rendu de la conférence
Indexation
-
Evaluación de las prestaciones de acondicionado...
- Auteurs : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
- Date : 03/2011
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 39 - n. 434
- Formats : PDF
Voir la fiche
-
Valutazione delle prestazioni dei condizionator...
- Auteurs : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
- Date : 2010
- Langues : Italien
- Source : Industria & Formazione - vol. 34 - n. 344
- Formats : PDF
Voir la fiche
-
Performance assessment of air conditioners with...
- Auteurs : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
- Date : 08/2010
- Langues : Anglais
- Source : IIF, Note Inf./IIR, Inf. Note/Bull. IIF-IIR/www.iifiir.org - vol. 90 - n. 2010-4
- Formats : PDF
Voir la fiche
-
Experimental assessment of HC-290 as a drop-in ...
- Auteurs : DEVOTTA S., PADALKAR A. S., SANE N. K.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Expérience sur le remplacement du R22 par le R2...
- Auteurs : LI T., YANG J., ZENG Z., et al.
- Date : 08/2010
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 31 - n. 4
- Formats : PDF
Voir la fiche