Résumé
The performance of HFO-1234yf as a substitute for R-134a was evaluated in a household freezer/refrigerator. A series of 'Refrigerant Charging Test', 'Pull-down Test', 'Cooling Speed Test' and 'Energy Consumption Test' were carried out under AHAM (Association of Home Appliance Manufacturer) standard. The results of drop-in test using two capillary tubes were compared with those of R-134a. During the test, capillary tube was considered as the key parameter to increase the speed of decrease in the compartment temperature. The results show that HFO-1234yf is as good as R-134a in a freezer/refrigerator performance but the diameter of capillary tube should be changed to sustain the performance. A larger diameter capillary tube was suggested to keep the cooling speed similar to that of
R-134a.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance evaluation of HFO-1234yf as a substitute for R-134a in a household freezer/refrigerator.
- Identifiant de la fiche : 30024829
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1127
Liens
- Voir aussi : Performance evaluation of HFO-1234yf as a substitute for R-134a in a household freezer/refrigerator.
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Refrigerant charge optimization in household re...
- Auteurs : MELO C.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
A capillary tube: refrigerant charge design met...
- Auteurs : BOENG J., MELO C.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Evaluation of R134a and R152a as working fluids...
- Auteurs : PANNOCK J., LIU Z., RADERMACHER R., YU K.
- Date : 1994
- Langues : Anglais
- Source : ASHRAE Transactions 1994.
Voir la fiche
-
Mapping the energy consumption of household ref...
- Auteurs : BOENG J., MELO C.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche