Document IIF

Évaluation de la performance du HFO-1234yf comme substitut au R-134a dans un réfrigérateur/congélateur domestique.

Performance evaluation of HFO-1234yf as a substitute for R-134a in a household freezer/refrigerator.

Numéro : pap. n. 1127

Auteurs : LEE J. S., LEE M. R., JEON S.

Résumé

This is the 12 slide PowerPoint presentation of Lee's paper.

The performance of HFO-1234yf as a substitute for R-134a was evaluated in a household freezer/refrigerator. A series of 'Refrigerant Charging Test', 'Pull-down Test', 'Cooling Speed Test' and 'Energy Consumption Test' were carried out under AHAM (Association of Home Appliance Manufacturer) standard. The results of drop-in test using two capillary tubes were compared with those of R-134a. During the test, capillary tube was considered as the key parameter to increase the speed of decrease in the compartment temperature. The results show that HFO-1234yf is as good as R-134a in a freezer/refrigerator performance but the diameter of capillary tube should be changed to sustain the performance. A larger diameter capillary tube was suggested to keep the cooling speed similar to that of R-134a.

Documents disponibles

Format PDF

Pages : 12

Disponible

Gratuit

Détails

  • Titre original : Performance evaluation of HFO-1234yf as a substitute for R-134a in a household freezer/refrigerator.
  • Identifiant de la fiche : 30024955
  • Langues : Anglais
  • Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
  • Date d'édition : 09/2018

Liens


Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence