Document IIF
Évaluation des performances d'un réfrigérateur MT à petite échelle bi-étagé au CO2.
Performance assessment of a two-stage CO2 small scale MT refrigerator.
Auteurs : CITARELLA B., MASTRULLO R., MAURO A. W., SFRAGARA M., TAMMARO M.
Type d'article : Article de la RIF
Résumé
F-GAS regulation has introduced important limitations in the use of refrigerants in the small size commercial refrigeration sector, with a maximum GWP=150 since 2022, forbidding the use of R404A. Among alternatives, there are propane, low-GWP HFC/HFO mixtures or pure HFOs: each of them can be considered as an option depending on the refrigerant charge limit for the application or by the total cost accepted by customer. In case of remotely connected units with potential refrigerant leakages, such as condensing units, the use of CO2 is considered as an option, due to the its safety indexes (no toxic and no flammable) which enables the use of larger amount of refrigerant. Being the CO2 refrigerant cycle trans-critical in warm climates, it may have low COPs and not fulfil the limits imposed by Ecodesign rules. In this paper, a condensing unit working with R744 is experimentally tested to assess the performance according to EN13215:2016. To limit high temperature at the compressor outlet, a two-stage system working with an inverter-driven hermetic rolling piston compressor is considered with intercooler and flash gas removal at intermediate pressure. It has been verified that seasonal energy performance ratio (SEPR) can be over the threshold value of 2.3 applied since 2018.
Documents disponibles
Format PDF
Pages : 887-896
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance assessment of a two-stage CO2 small scale MT refrigerator.
- Identifiant de la fiche : 30029192
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Date d'édition : 11/2021
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.12.024
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (95)
Voir la source
Indexation
-
Performance measurements of a two stage CO2 ref...
- Auteurs : CITARELLA B., MASTRULLO R., MAURO A., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Oil sensible semi-empirical two-stage rotary CO...
- Auteurs : VEGA J., SACASAS D., LECLERCQ N., CUEVAS C., LEMORT V.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Transcritical CO2 system with two-st...
- Auteurs : LIU S., LI J., DAI B., WANG J., ZHANG Q.
- Date : 10/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 166
- Formats : PDF
Voir la fiche
-
R744 refrigeration solution for small supermark...
- Auteurs : SINGH S., PARDINAS A., HAFNER A., SCHLEMMINGER C., BANASIAK K.
- Date : 16/09/2021
- Langues : Anglais
- Source : 9th IIR Conference on Ammonia and CO2 Refrigeration Technologies. Proceedings: Ohrid, North Macedonia, 16-17 September, 2021
- Formats : PDF
Voir la fiche
-
Theoretical evaluation of transcritical CO2 sys...
- Auteurs : SAWALHA S.
- Date : 05/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 3
- Formats : PDF
Voir la fiche