Subcooling of the refrigerant before expanding it to the evaporator pressure in a transcritical carbon dioxide (CO2) refrigeration system considerably improves the system's performance. This numerical study uses the refrigerating effect generated in a heat-driven ejector refrigeration system to subcool the CO2 refrigerant. The heat of the CO2 refrigerant at the compressor exit is used to drive the heat-driven ejector refrigeration system. Further, in another configuration, an internal heat exchanger (IHX) is utilised to subcool the refrigerant. The performance analysis of the heat-driven ejector cooling assisted transcritical CO2 refrigeration system with and without the IHX has been performed. The parametric study has been carried out for various variables, while the low temperature evaporator and the medium temperature evaporator are maintained at -30 °C and -10 °C, respectively. The maximum improvement in the Coefficient of performance (COP) for the proposed system has been observed about 14.2 % and 50.4 % as compared to parallel compression refrigeration system and booster refrigeration system, respectively.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance evaluation of a transcritical CO2 refrigeration system for supermarkets in hot climatic conditions.
- Identifiant de la fiche : 30032728
- Langues : Anglais
- Source : 16th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2024). Proceedings. University of Maryland, College Park, Maryland, USA, August 11-14 2024
- Date d'édition : 08/2024
- DOI : http://dx.doi.org/10.18462/iir.gl2024.1221
Liens
Voir d'autres communications du même compte rendu (135)
Voir le compte rendu de la conférence
Indexation
-
A novel IMS-ejector based supermarket CO2<...
- Auteurs : SENGUPTA A., DASGUPTA M. S.
- Date : 27/04/2023
- Langues : Anglais
- Source : 10th IIR Conference on Ammonia and CO2 Refrigeration Technologies.
- Formats : PDF
Voir la fiche
-
Simulation and optimization of a R744 two- temp...
- Auteurs : HUANG Z., ZHAO H., YU Z., et al.
- Date : 06/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 90
- Formats : PDF
Voir la fiche
-
Experimental evaluation of a multi-ejector tran...
- Auteurs : SINGH S., HAFNER A., BANASIAK K., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Performance analysis of a modified dual-ejector...
- Auteurs : LIU J., YU J.
- Date : 11/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Formats : PDF
Voir la fiche
-
Possible configurations of multiejector driven ...
- Auteurs : BLUST S., HAFNER A., BANASIAK K., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche